Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 29(Pt 6): 1480-1494, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36345756

RESUMO

The highly automated macromolecular crystallography beamline AMX/17-ID-1 is an undulator-based high-intensity (>5 × 1012 photons s-1), micro-focus (7 µm × 5 µm), low-divergence (1 mrad × 0.35 mrad) energy-tunable (5-18 keV) beamline at the NSLS-II, Brookhaven National Laboratory, Upton, NY, USA. It is one of the three life science beamlines constructed by the NIH under the ABBIX project and it shares sector 17-ID with the FMX beamline, the frontier micro-focus macromolecular crystallography beamline. AMX saw first light in March 2016 and started general user operation in February 2017. At AMX, emphasis has been placed on high throughput, high capacity, and automation to enable data collection from the most challenging projects using an intense micro-focus beam. Here, the current state and capabilities of the beamline are reported, and the different macromolecular crystallography experiments that are routinely performed at AMX/17-ID-1 as well as some plans for the near future are presented.


Assuntos
Síncrotrons , Cristalografia por Raios X , Substâncias Macromoleculares/química
3.
J Synchrotron Radiat ; 28(Pt 5): 1649-1661, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34475312

RESUMO

Here we present two robotic sample changers integrated into the experimental stations for the macromolecular crystallography (MX) beamlines AMX and FMX, and the biological small-angle scattering (bioSAXS) beamline LiX. They enable fully automated unattended data collection and remote access to the beamlines. The system designs incorporate high-throughput, versatility, high-capacity, resource sharing and robustness. All systems are centered around a six-axis industrial robotic arm coupled with a force torque sensor and in-house end effectors (grippers). They have the same software architecture and the facility standard EPICS-based BEAST alarm system. The MX system is compatible with SPINE bases and Unipucks. It comprises a liquid nitrogen dewar holding 384 samples (24 Unipucks) and a stay-cold gripper, and utilizes machine vision software to track the sample during operations and to calculate the final mount position on the goniometer. The bioSAXS system has an in-house engineered sample storage unit that can hold up to 360 samples (20 sample holders) which keeps samples at a user-set temperature (277 K to 300 K). The MX systems were deployed in early 2017 and the bioSAXS system in early 2019.


Assuntos
Cristalografia por Raios X/métodos , Substâncias Macromoleculares/química , Robótica/métodos , Desenho de Equipamento , Espalhamento a Baixo Ângulo , Software , Síncrotrons , Raios X
4.
J Synchrotron Radiat ; 28(Pt 2): 650-665, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33650577

RESUMO

Two new macromolecular crystallography (MX) beamlines at the National Synchrotron Light Source II, FMX and AMX, opened for general user operation in February 2017 [Schneider et al. (2013). J. Phys. Conf. Ser. 425, 012003; Fuchs et al. (2014). J. Phys. Conf. Ser. 493, 012021; Fuchs et al. (2016). AIP Conf. Proc. SRI2015, 1741, 030006]. FMX, the micro-focusing Frontier MX beamline in sector 17-ID-2 at NSLS-II, covers a 5-30 keV photon energy range and delivers a flux of 4.0 × 1012 photons s-1 at 1 Šinto a 1 µm × 1.5 µm to 10 µm × 10 µm (V × H) variable focus, expected to reach 5 × 1012 photons s-1 at final storage-ring current. This flux density surpasses most MX beamlines by nearly two orders of magnitude. The high brightness and microbeam capability of FMX are focused on solving difficult crystallographic challenges. The beamline's flexible design supports a wide range of structure determination methods - serial crystallography on micrometre-sized crystals, raster optimization of diffraction from inhomogeneous crystals, high-resolution data collection from large-unit-cell crystals, room-temperature data collection for crystals that are difficult to freeze and for studying conformational dynamics, and fully automated data collection for sample-screening and ligand-binding studies. FMX's high dose rate reduces data collection times for applications like serial crystallography to minutes rather than hours. With associated sample lifetimes as short as a few milliseconds, new rapid sample-delivery methods have been implemented, such as an ultra-high-speed high-precision piezo scanner goniometer [Gao et al. (2018). J. Synchrotron Rad. 25, 1362-1370], new microcrystal-optimized micromesh well sample holders [Guo et al. (2018). IUCrJ, 5, 238-246] and highly viscous media injectors [Weierstall et al. (2014). Nat. Commun. 5, 3309]. The new beamline pushes the frontier of synchrotron crystallography and enables users to determine structures from difficult-to-crystallize targets like membrane proteins, using previously intractable crystals of a few micrometres in size, and to obtain quality structures from irregular larger crystals.


Assuntos
Síncrotrons , Cristalografia , Cristalografia por Raios X , Coleta de Dados , Substâncias Macromoleculares , Viscosidade
5.
Acta Crystallogr E Crystallogr Commun ; 76(Pt 7): 1136-1138, 2020 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-32695467

RESUMO

Exceptionally large crystals of posnjakite, Cu4SO4(OH)6(H2O), formed during corrosion of a Swagelock(tm) Snubber copper gasket within the MX1 beamline at the ANSTO-Melbourne, Australian Synchrotron. The crystal structure was solved using synchrotron radiation to R 1 = 0.029 and revealed a structure based upon [Cu4(OH)6(H2O)O] sheets, which contain Jahn-Teller-distorted Cu octa-hedra. The sulfate tetra-hedra are bonded to one side of the sheet via corner sharing and linked to successive sheets via extensive hydrogen bonds. The sulfate tetra-hedra are split and rotated, which enables additional hydrogen bonds.

6.
J Synchrotron Radiat ; 25(Pt 3): 885-891, 2018 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-29714201

RESUMO

MX2 is an in-vacuum undulator-based crystallography beamline at the 3 GeV Australian Synchrotron. The beamline delivers hard X-rays in the energy range 4.8-21 keV to a focal spot of 22 × 12 µm FWHM (H × V). At 13 keV the flux at the sample is 3.4 × 1012 photons s-1. The beamline endstation allows robotic handling of cryogenic samples via an updated SSRL SAM robot. This beamline is ideal for weakly diffracting hard-to-crystallize proteins, virus particles, protein assemblies and nucleic acids as well as smaller molecules such as inorganic catalysts and organic drug molecules. The beamline is now mature and has enjoyed a full user program for the last nine years. This paper describes the beamline status, plans for its future and some recent scientific highlights.

7.
J Synchrotron Radiat ; 22(3): 853-8, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25931106

RESUMO

Synchrotron light source facilities worldwide generate terabytes of data in numerous incompatible data formats from a wide range of experiment types. The Data Analysis WorkbeNch (DAWN) was developed to address the challenge of providing a single visualization and analysis platform for data from any synchrotron experiment (including single-crystal and powder diffraction, tomography and spectroscopy), whilst also being sufficiently extensible for new specific use case analysis environments to be incorporated (e.g. ARPES, PEEM). In this work, the history and current state of DAWN are presented, with two case studies to demonstrate specific functionality. The first is an example of a data processing and reduction problem using the generic tools, whilst the second shows how these tools can be targeted to a specific scientific area.

8.
Acta Crystallogr D Biol Crystallogr ; 70(Pt 5): 1248-56, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24816094

RESUMO

A departure from a linear or an exponential intensity decay in the diffracting power of protein crystals as a function of absorbed dose is reported. The observation of a lag phase raises the possibility of collecting significantly more data from crystals held at room temperature before an intolerable intensity decay is reached. A simple model accounting for the form of the intensity decay is reintroduced and is applied for the first time to high frame-rate room-temperature data collection.


Assuntos
Cristalografia por Raios X/métodos , Cristalografia por Raios X/instrumentação , Enterovirus Bovino/química , Vírus da Febre Aftosa/química , Modelos Teóricos , Proteínas/química , Temperatura
9.
Acta Crystallogr D Biol Crystallogr ; 68(Pt 5): 592-600, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22525757

RESUMO

Despite significant progress in high-throughput methods in macromolecular crystallography, the production of diffraction-quality crystals remains a major bottleneck. By recording diffraction in situ from crystals in their crystallization plates at room temperature, a number of problems associated with crystal handling and cryoprotection can be side-stepped. Using a dedicated goniometer installed on the microfocus macromolecular crystallography beamline I24 at Diamond Light Source, crystals have been studied in situ with an intense and flexible microfocus beam, allowing weakly diffracting samples to be assessed without a manual crystal-handling step but with good signal to noise, despite the background scatter from the plate. A number of case studies are reported: the structure solution of bovine enterovirus 2, crystallization screening of membrane proteins and complexes, and structure solution from crystallization hits produced via a high-throughput pipeline. These demonstrate the potential for in situ data collection and structure solution with microbeams.


Assuntos
Bactérias/química , Proteínas de Bactérias/química , Cristalização/instrumentação , Cristalografia por Raios X/instrumentação , Enterovirus Bovino/química , Infecções por Enterovirus/virologia , Desenho de Equipamento , Complexos Multiproteicos/química
10.
Acta Crystallogr D Biol Crystallogr ; 66(Pt 9): 1032-5, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20823554

RESUMO

A novel raster-scanning method combining continuous sample translation with the fast readout of a Pilatus P6M detector has been developed on microfocus beamline I24 at Diamond Light Source. This fast grid-scan tool allows the rapid evaluation of large sample volumes without the need to increase the beam size at the sample through changes in beamline hardware. A slow version is available for slow-readout detectors. Examples of grid-scan use in centring optically invisible samples and in detecting and characterizing numerous microcrystals on a mesh-like holder illustrate the most common applications of the grid scan now in routine use on I24.


Assuntos
Cristalografia por Raios X/métodos , Cristalografia por Raios X/instrumentação , Fatores de Tempo
11.
Acta Crystallogr D Biol Crystallogr ; 61(Pt 10): 1354-63, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16204887

RESUMO

Automatic fitting methods that build molecules into electron-density maps usually fail below 3.5 A resolution. As a first step towards addressing this problem, an algorithm has been developed using an approximation of the medial axis to simplify an electron-density isosurface. This approximation captures the central axis of the isosurface with a graph which is then matched against a graph of the molecular model. One of the first applications of the medial axis to X-ray crystallography is presented here. When applied to ligand fitting, the method performs at least as well as methods based on selecting peaks in electron-density maps. Generalization of the method to recognition of common features across multiple contour levels could lead to powerful automatic fitting methods that perform well even at low resolution.


Assuntos
Cristalografia por Raios X/métodos , Elétrons , Substâncias Macromoleculares/química , Algoritmos , Automação , Ligantes , Modelos Moleculares , Modelos Estatísticos , Conformação Molecular , Reconhecimento Automatizado de Padrão , Conformação Proteica , Proteínas/química
12.
Proteins ; 51(4): 544-51, 2003 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-12784213

RESUMO

The 2.1-A resolution crystal structure of the MATalpha2 homeodomain bound to DNA reveals the unexpected presence of two nonspecifically bound alpha2 homeodomains, in addition to the two alpha2 homeodomains bound to canonical alpha2 binding sites. One of the extra homeodomains makes few base-specific contacts, while the other extra homeodomain binds to DNA in a previously unobserved manner. This unusually bound homeodomain is rotated on the DNA, making possible major groove contacts by side-chains that normally do not contact the DNA. This alternate docking may represent one way in which homeodomains sample nonspecific DNA sequences.


Assuntos
Proteínas de Ligação a DNA/química , DNA/química , Proteínas de Homeodomínio/química , Proteínas Repressoras/química , Sequência de Aminoácidos , Sequência de Bases , Sítios de Ligação/genética , Cristalografia por Raios X , DNA/genética , DNA/metabolismo , Proteínas de Ligação a DNA/genética , Proteínas de Ligação a DNA/metabolismo , Proteínas Fúngicas/química , Proteínas Fúngicas/genética , Proteínas Fúngicas/metabolismo , Proteínas de Homeodomínio/genética , Proteínas de Homeodomínio/metabolismo , Ligação de Hidrogênio , Modelos Moleculares , Dados de Sequência Molecular , Conformação de Ácido Nucleico , Ligação Proteica , Conformação Proteica , Proteínas Repressoras/genética , Proteínas Repressoras/metabolismo , Homologia de Sequência de Aminoácidos
13.
Nucleic Acids Res ; 30(23): 5244-52, 2002 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-12466549

RESUMO

Hoogsteen base pairs within duplex DNA typically are only observed in regions containing significant distortion or near sites of drug intercalation. We report here the observation of a Hoogsteen base pair embedded within undistorted, unmodified B-DNA. The Hoogsteen base pair, consisting of a syn adenine base paired with an anti thymine base, is found in the 2.1 A resolution structure of the MATalpha2 homeodomain bound to DNA in a region where a specifically and a non-specifically bound homeodomain contact overlapping sites. NMR studies of the free DNA show no evidence of Hoogsteen base pair formation, suggesting that protein binding favors the transition from a Watson-Crick to a Hoogsteen base pair. Molecular dynamics simulations of the homeodomain-DNA complex support a role for the non-specifically bound protein in favoring Hoogsteen base pair formation. The presence of a Hoogsteen base pair in the crystal structure of a protein-DNA complex raises the possibility that Hoogsteen base pairs could occur within duplex DNA and play a hitherto unrecognized role in transcription, replication and other cellular processes.


Assuntos
DNA/química , Pareamento de Bases , Sequência de Bases , Sítios de Ligação , Simulação por Computador , Cristalografia por Raios X , DNA/metabolismo , Proteínas de Ligação a DNA/metabolismo , Proteínas de Homeodomínio/química , Proteínas de Homeodomínio/metabolismo , Modelos Moleculares , Ressonância Magnética Nuclear Biomolecular , Proteínas Repressoras/química , Proteínas Repressoras/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...